WR1001

Applicable voltage: DC 4.5-6V Applicable water pressure: 0.02-1.0MPa Applicable fluid: 1-60 ℃ public water Pulse width: 30-100mS Water inlet and outlet specifications: inlet G3/4, outlet G1/2 Installation distance: 53.5mm Installation aperture: Ø4.5mm Flow characteristics: >21L/min(0.08MPa)

WR1002

Applicable voltage: DC 4.5-6V Applicable water pressure: 0.02-1.0MPa Applicable fluid: 1-60 ℃ public water Pulse width: 30-100mS Water inlet and outlet specifications: inlet G3/4, outlet G1/2 Installation pitch:/ Installation aperture:/ Flow characteristics: >10L/min(0.05MPa)

WR1003

Applicable voltage: DC 4.5-6V Applicable water pressure: 0.02-1.0MPa Applicable fluid: 1-60 ℃ public water Pulse width: 30-100mS Water inlet and outlet specifications: G3/4 Installation space: 54mm Installation aperture: Ø4.5mm Flow characteristics: >8L/min(0.08MPa)

WR1004

Applicable voltage: DC 4.5-6V Applicable water pressure: 0.02-1.0MPa Applicable fluid: 1-60 ℃ public water Pulse width: 30-100mS Water inlet and outlet specifications: G3/4 Installation space: 54mm Installation aperture: Ø4.5mm Flow characteristics: >8L/min(0.08MPa)

WR1005

Applicable voltage: DC 4.5-6V Applicable water pressure: 0.02-1.0MPa Applicable fluid: 1-60 ℃ public water Pulse width: 30-100mS Water inlet and outlet specifications: G3/4 Installation pitch:/ Installation aperture:/ Flow characteristics: >8L/min(0.05MPa)

WR1006

Applicable voltage: DC 4.5-6V Applicable water pressure: 0.02-1.0MPa Applicable fluid: 1-60 ℃ public water Pulse width: 30-100mS Water inlet and outlet specifications: G3/4 Installation pitch:/ Installation aperture:/ Flow characteristics: >8L/min(0.05MPa)

WD1001

Applicable voltage: DC12-36V, AC100-220V Applicable water pressure 0.02-1.0MPa Applicable fluid: 1-80 ℃ public water Terminal orientation: 90º, 180º, 270º, 360º Water inlet and outlet specifications: inlet G3/4, outlet Ø16mm Installation space: 32mm Installation aperture: Ø4.2mm Flow characteristics: 13-20L/min (0.1-1.0MPa)

WD1002

Applicable voltage: DC12-36V, AC100-220V Applicable water pressure 0.02-1.0MPa Applicable fluid: 1-80 ℃ public water Water inlet and outlet specifications: inlet Ø11mm, outlet Ø6.4mm Installation pitch:/ Installation aperture: Ø4.2mm Dynamic pressure of water outlet: 0.1±0.02MPa (with nozzle) Flow characteristics: 850±50mL/min (0.15-0.8MPa)

WD1003

Applicable voltage: DC12-36V, AC100-220V Applicable water pressure 0.02-1.0MPa Applicable fluid: 1-80 ℃ public water Water inlet and outlet specifications: inlet Ø13mm, outlet Ø7.2mm Installation space: 48mm Installation aperture: Ø4.3mm Dynamic pressure of water outlet: 0.1±0.02MPa (with nozzle) Flow characteristics: 850±50mL/min (0.15-0.8MPa)

WD1004

Applicable voltage: DC12-36V, AC100-220V Applicable water pressure 0.02-1.0MPa Applicable fluid: 1-80 ℃ public water Water inlet and outlet specifications: Ø6.4mm Installation space: 48mm Installation aperture: Ø4.2mm Dynamic pressure of water outlet: 0.1±0.02MPa (with nozzle) Flow characteristics: 850±50mL/min (0.15-0.8MPa)

WD1005

Applicable voltage: DC12-36V, AC100-220V Applicable water pressure 0.02-1.0MPa Applicable fluid: 1-80 ℃ public water Water inlet and outlet specifications: Ø6.4mm Installation pitch:/ Installation aperture: / Dynamic pressure of water outlet: 0.1±0.02MPa (with nozzle) Flow characteristics: 850±50mL/min (0.15-0.8MPa)

WD1006

Applicable voltage: DC12-36V, AC100-220V Applicable water pressure 0.02-1.0MPa Applicable fluid: 1-80 ℃ public water Water inlet and outlet specifications: inlet Ø15mm, outlet Ø10mm Installation pitch:/ Installation aperture: / Dynamic pressure of water outlet: 0.1±0.02MPa (with nozzle) Flow characteristics: 0.8-1.2L/min (0.15-0.8MPa)
< 12 >